Continuous Blowdown Tank


The continuous blowdown flash tank is connected to the boiler’s continuous blowdown outlet and serves to reduce the pressure and expand the volume of the boiler’s continuous blowdown before discharging it. The secondary steam is routed through a dedicated pipeline, typically to the deaerator, while the waste hot water is automatically discharged via a float‑type level control valve or an overflow‑adjustment valve, usually into a fixed‑drain flash tank, allowing the thermal energy to be recovered and reused. The continuous blowdown flow rate is automatically adjusted in response to changes in the boiler feedwater load, maintaining a relatively stable blowdown rate. By utilizing the secondary steam and waste hot water as heat sources, a portion of the heat lost in the boiler’s continuous blowdown can be recovered, thereby improving boiler efficiency.


Category:

Query

Keywords:

Blowdown Tank

Product Introduction

Continuous Blowdown Tank

The continuous blowdown tank is connected to the boiler’s continuous blowdown outlet and serves to reduce the pressure and expand the volume of the boiler’s continuous blowdown before discharging it. The secondary steam is routed through a dedicated pipeline, typically to the deaerator, while the waste hot water is automatically discharged via a float‑type level control valve or an overflow‑adjustment valve, usually into a fixed‑drain flash tank, allowing the thermal energy to be recovered and reused. The continuous blowdown flow rate is automatically adjusted in response to changes in the boiler feedwater load, maintaining a relatively stable blowdown rate. By utilizing the secondary steam and waste hot water as heat sources, a portion of the heat lost in the boiler’s continuous blowdown can be recovered, thereby improving boiler efficiency.

Structure and Function

The expansion vessel consists of a main body, auxiliary components, and other parts. The main body comprises a cylindrical shell, elliptical end caps, a manhole, and internal fittings. These internal fittings include wear‑resistant devices, cooling water inlet assemblies, and overflow devices, among others.

Project Location

Customer Name

Project Name

 

QTY.

Continuous Blowdown Tank & Periodic Blowdown Tank

Australia

Ameco Foster Wheeler

Port Pirie Waste Heat Boiler Project, Australia

Intermittent Blowdown Tank

1

Morocco

Shandong Electric Power Construction No. 3 Engineering Co., Ltd.

Morocco Noor III 150 MW Concentrated Solar Power Plant Project

Blowdown Tank

5

Philippines

Ameco Foster Wheeler

Philippine SEC 210-1 × 105 MW coal-fired power plant

Continuous Blowdown Tank

Intermittent Blowdown Tank

4

Malaysia

Shanghai Boiler Works Co., Ltd.

Malaysia Liwen 1 × 260 t/h Biomass–Coal CFB Boiler and Auxiliary Systems Project

Continuous Blowdown Tank

Intermittent Blowdown Tank

2

Russia

China Fifth Ring Engineering Co., Ltd.

Russia’s Syzran Fertilizer Project

Blowdown Tank

3

Singapore

Jiangsu Haitong Economic and Trade Co., Ltd.

Singapore Tuas 300 TPD Waste-to-Energy Project

Blowdown Tank

Gas storage tank

9

Maldives

Jiangsu Haitong Economic and Trade Co., Ltd. (China Tianying Co., Ltd., CNTY)

Maldives Energy and Waste Management Waste-to-Energy Project

Blowdown Tank

3

Saudi Arabia

Oriental Lingri Boiler Co., Ltd.

Saudi Al-Jafra Project

Continuous Blowdown Tank

Intermittent Blowdown Tank

2

Indonesia

Shanghai HaiGuo Technology Co., Ltd.

Indonesia Oman 900 KTPA AMIN Self-Provided Copper Smelting Plant Project

Intermittent Blowdown Tank

4

Gambia

Tianjin Gela Gas Compression Equipment Co., Ltd.

Gambia GGC Biomass Power Plant Project

Intermittent Blowdown Tank

Hydrophobic expansion vessel

5

Thailand

Chongqing Sanfeng Cavantha Environmental Industry Co., Ltd.

Thailand Chokchai 9.9 MW WTE Project

Deaerator

Blowdown Tank

4

South Korea

Sumitomo Heavy Industries Fuhui Energy Management (Shanghai) Co., Ltd.

Korean TW Project

Atmospheric Flash Drum

Continuous Blowdown Tank

2

Malaysia

Oriental Lingri Boiler Co., Ltd.

Malaysia Miri Gas-fired Power Plant Project

Continuous Blowdown Tank

Intermittent Blowdown Tank

2

Iraq

Oriental Lingri Boiler Co., Ltd.

Iraq Zubair Gas Turbine Unit Single-to-Combined Project

Continuous Blowdown Tank

Intermittent Blowdown Tank

2

Brazil

Valmet Technology Co., Ltd.

Brazil

Intermittent Blowdown Tank

Continuous Blowdown Tank

2

Saudi Arabia

Oriental Lingri Boiler Co., Ltd.

Saudi Gazlan Combined-Cycle Gas Power Plant Expansion Project

Intermittent Blowdown Tank

Continuous Blowdown Tank

16

Hydrophobic expansion vessel

Oman

Shandong Electric Power Construction No. 3 Engineering Co., Ltd.

Oman Salalah Phase II 430 MW Gas-Fired Combined-Cycle Power Plant Project

Hydrophobic expansion vessel

8

Jordan

Shandong Electric Power Construction No. 3 Engineering Co., Ltd.

Jordan Samareh Phase IV 66.4 MW Combined-Cycle Expansion Project

Hydrophobic expansion vessel

1

Japan

Andritz Austria

Japan Ichihara Project

Hydrophobic expansion vessel

2

United Arab Emirates

Shandong Electric Power Construction No. 3 Engineering Co., Ltd.

UAE DUBAL 550 MW Combined-Cycle Power Plant

Hydrophobic expansion vessel

1

Bahrain

Shandong Electric Power Construction No. 3 Engineering Co., Ltd.

Bahrain Adu Phase II Independent Water Plant and Power Station Project

Hydrophobic expansion vessel

4

Bangladesh

China Energy Construction Group Northeast Electric Power First Engineering Company

Meghnaghat PhaseⅡFuel Gas589.75MW/Fuel Oil 541.22MW Combined Cycle Power Station Project, Bangladesh

Hydrophobic expansion vessel

1

Indonesia

Sumitomo Heavy Industries Fuhui Energy Management (Shanghai) Co., Ltd.

Indonesia Mania Smelter Project

Hydrophobic expansion vessel

2

Uzbekistan

China Energy Construction Group Zhejiang Thermal Power Construction Co., Ltd.

Uzbekistan Syr Darya 1,500 MW Gas-Fired Combined-Cycle Independent Power Plant

Hydrophobic expansion vessel

1

Saudi Arabia

Shandong Electric Power Construction No. 3 Engineering Co., Ltd.

Saudi Taiba 1,800 MW Combined-Cycle Power Plant Project

Blowdown Tank

21

Singapore

Shandong Electric Power Construction No. 3 Engineering Co., Ltd.

Singapore CCP50 600 MW Combined-Cycle Power Plant Project

Blowdown Tank

4

Manual Download

Product Certification

EU PED Certification Certificate

EU PED Certification Certificate

Canadian CRN Certificate

Canadian CRN Certificate

DOSH-certificate

DOSH-certificate

Uzbekistan GOST Certification

Uzbekistan GOST Certification

Equipment Display

Impact testing machine
Automatic Flat Plate Edge Milling Machine (Beveling Machine)
Universal (Tensile) Testing Machine
Low-Temperature Impact Tester
Direct-reading spectrometer
Helium mass spectrometer leak detector
Weishi hardness tester
Leeb (portable) hardness tester
Richter (Portable) Spectrometer
Impact test specimen tensile testing machine

Customer Feedback

Customer Message 1
Customer Message 2

Request a quote now

Please provide your contact information and specify your requirements, and we will arrange for a dedicated representative to get in touch with you.

  • 你需要多少产品?
  • 你还需要了解哪些信息?
Submit

Continuous Blowdown Tank


The continuous blowdown flash tank is connected to the boiler’s continuous blowdown outlet and serves to reduce the pressure and expand the volume of the boiler’s continuous blowdown before discharging it. The secondary steam is routed through a dedicated pipeline, typically to the deaerator, while the waste hot water is automatically discharged via a float‑type level control valve or an overflow‑adjustment valve, usually into a fixed‑drain flash tank, allowing the thermal energy to be recovered and reused. The continuous blowdown flow rate is automatically adjusted in response to changes in the boiler feedwater load, maintaining a relatively stable blowdown rate. By utilizing the secondary steam and waste hot water as heat sources, a portion of the heat lost in the boiler’s continuous blowdown can be recovered, thereby improving boiler efficiency.


Category:

Keywords:

Blowdown Tank

Contact Us

Sales Department Phone:

Tel: +86-0531-87510324

Fax: +86-0531-87983154

After-sales Service Department Phone:

Tel: +86-0531-87510324

Company email:

Email: jpvf@jirong.net.cn

Email: sales@jirong-thermal.com

Company Address:

Mailing Address: No. 18 Huaxin Road, Jinan City, Shandong Province

WeChat Official Account

 WeChat Official Account

Please tell us your requirements.

We recommend and carefully select suitable products for you.

More products More +

High-pressure Rotating Film Deaerator


High adaptability: It can achieve deoxygenation under conditions of low‑temperature influent and high‑oxygen‑content influent, provided that a sufficient steam flow is maintained.

Low-pressure Rotating Film Deaerator


High adaptability: It can achieve deoxygenation under conditions of low‑temperature influent and high‑oxygen‑content influent, provided that a sufficient steam flow is maintained.